DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-294CARR-POW (Carrier Port Power Unit) for DC-Powered Systems
10
Power Unit Query Test (#127)
This test queries the Maintenance/Tape Processor in a Standard system PPN, the
Duplication Interface circuit pack in a PPN for a High or Critical Reliability
system, or the EPN Maintenance circuit pack in an EPN multicarrier cabinet
system for the status of the pair of port carrier power units in the specified carrier.
If both port carrier units are on and functioning, the test passes. If both are not on
and functioning, the test fails.
PASS Both port carrier power units in the recycled
carrier were found to be healthy by the
Maintenance/Tape Processor in Standard system
PPN, the Duplication Interface circuit pack in a
PPN for a High or Critical Reliability system, or the
EPN Maintenance circuit pack in an EPN
multicarrier cabinet system after the port carrier
power units were powered-down and powered up
again. If the status LEDs on both port carrier
power units are not showing green, then the
PR-MAINT (Maintenance/Tape Processor),
DUPINT (Duplication Interface) circuit pack, or the
EPN MAINT (Maintenance) circuit pack may have
incorrectly reported the state of the port carrier
power units. Look for and resolve any alarms on
these MOs.
Table 10-85. TEST #127 Power Unit Query Test
Error
Code
Test
Result Description/ Recommendation
1000 ABORT System resources required to run this test are not
available.
2000 ABORT Response to the test request was not received within the
allowable time period.
Continued on next page
Table 10-84. TEST #126 Power Unit Recycle Test — Continued
Error Code
Test
Result Description/ Recommendation
Continued on next page