DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-41ADX16A-PT (AUDIX Analog Line/Control Link)
10
Note:
a. Retry the command at 1-minute intervals a maximum of 5 times
Conference Circuit Test (#7)
This test verifies that the NPE channel for the port being tested can correctly
perform the conferencing function.
PASS The port is correctly using its allocated time slots. User-reported troubles
on this port should be investigated by using other port tests, by examining
station wiring, or by examining the station.
Table 10-17. TEST #7 Conference Circuit Test
Error
Code
Test
Result Description/Recommendation
ABORT Could not allocate the necessary system resources to run this test. (a)
1000 ABORT System resources required to run test are not available. The port may be busy
with a valid call. Use the display port PCSSpp command to determine the
station extension. Use the status station command to determine the service
state of the port. If the port is in use, wait until it is idle before retesting.(a)
1004 ABORT The port was seized by a valid call during the test. The test has been aborted.
Use the display port PCSSpp command to determine the station extension.
Use the status station command to determine the service state of the port. If
the port is in use, wait until it is idle before testing. Try (a).
1018 ABORT Test disabled by administration. This only applies to analog stations.
1. To enable the test for the analog station being tested, enter the change
station <extension> command and change the ‘‘Test?’’ field on the
Station Form from ‘‘n’’ to ‘‘y.’’
2000 ABORT Response to the test request was not received within the allowable time period.
2100 ABORT Could not allocate the necessary system resources for this test. Try (a).
Continued on next page
Table 10-16. TEST #6 NPE Crosstalk Test — Continued
Error
Code
Test
Result Description/ Recommendation
Continued on next page