DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-1534UDS1-BD (UDS1 Interface Circuit Pack)
10
1313(q) Any CPE Loopback
Jack Test
(#1212)
MIN/ WRN
3
OFF test ds1-loop PCSS
end-loopback/span-test
1314(r) Any Far CSU
Loopback Test
(#1213)
MIN/ WRN
3
OFF test ds1-loop PCSS
end-loopback/span-
1320 Any Loss of Signal
Alarm Inquiry
Test (#138)
MIN/ WRN
3
OFF test board PCSS
1321 Any Loss of Signal
Alarm Inquiry
Test (#138)
MIN/ WRN
3
OFF test board PCSS
1322 Any Loss of Signal
Alarm Inquiry
Test (#138)
MINOR ON test board PCSS
1323 Any Loss of Signal
Alarm Inquiry
Test (#138)
MIN/ WRN
3
OFF test board PCSS
1324 Any Loss of Signal
Alarm Inquiry
Test (#138)
WARNING OFF test board PCSS
1537(s) 46082 MIN/ WRN
3
ON
1538(t) Any MIN/ WRN
3
ON
1793 Any Blue Alarm
Inquiry Test
(#139)
MAJ/MIN/
WRN
4
OFF test board PCSS
1794 Any Blue Alarm
Inquiry Test
(#139)
MAJ/MIN/
WRN
4
OFF test board PCSS
1795 Any Blue Alarm
Inquiry Test
(#139)
MAJ/MIN/
WRN
4
OFF test board PCSS
2049 Any Red Alarm
Inquiry Test
(#140)
MIN/ WRN
3
OFF test board PCSS
Table 10-454. DS1 Interface Circuit Pack Maintenance Error Log Entries — Continued
Error
Type
Aux
Data Associated Test
Alarm
Level
On/Off
Board Test to Clear Value
Continued on next page