DEFINITY Enterprise Communications Server Release 5
Maintenance and Test for R5vs/si
555-230-123
Issue 1
April 1997
Maintenance Object Repair Procedures
Page 10-1505TONE-PT (Tone Generator)
10
For a system with a TN768, TN780 or TN2182 Tone-Clock Circuit Pack
:
Notes:
a. Refer to XXX-BD (Common Port Circuit Pack) Maintenance documentation
for descriptions of these tests.
b. Refer to TONE-BD (Tone-Clock Circuit Pack) section for descriptions of
these tests.
c. Refer to TDM-CLK (TDM Bus Clock) section for descriptions of these tests.
d. This test only runs on the Standby Tone-Clock circuit pack in a Port
Network with more than one Tone-Clock circuit pack (High or Critical
Reliability Option). The circuit pack must be a TN780 code with firmware
revision 2 or above, or a TN2182.
1. D = Destructive; ND = Nondestructive
Order of Investigation
Short Test
Sequence
Long
Test
Sequence D/ND
1
SAKI Reset Test (#53) (a) X D
Clock Health Test (#46) (b) X X ND
Control Channel Loop Around Test
(#52) (a)
XXND
Tone Generator Crosstalk Test (#90) X ND
Tone Generator Transmission Test
(#40)
XXND
Tone Generator Audit/Update Test
(#41)
XXND
TDM Bus Clock Circuit Status Inquiry
Test (#148) (c)
XXND
TDM Bus Clock Slip Inquiry Test
(#149)(e)(c)
XXND
TDM Bus Clock PPM Inquiry Test
(#150) (c)
XXND
TDM Bus Clock Parameter Update Test
(#151) (c)
XX
Board Type Check Test (#574) (c) X X
Standby Reference Health Check Test
(#651) (c,d)
X